Insulation Thickness for Target R-Value Calculator
Find how thick a layer of your chosen insulation must be to bring an attic, wall or floor up to a target R-value.
Method reviewed October 26, 2026. Version 1.0.0. How it works
This is an estimate. It uses a simplified method and typical assumptions, all listed below. Use it to plan and to check quotes; equipment should be sized from a full room-by-room load calculation (ACCA Manual J) by a qualified professional.
Result
- Thickness to add
- 15.5in
- R-value to add
- 49h·ft²·°F/BTU
About 15.5 in of this product adds R-49 (2 layers of the R-30 product).
- Some products lose R-value per inch as they get thicker, and compressed batts lose R-value (an R-19 batt squeezed into a 3½ in cavity is rated about R-13). Check the product chart at your target R-value.
- Full layers of this product
- 2
- Implied R-value per inch of this product
- 3.16per in
Show the working
- R-value to add = target − existing49 − 0 = 49
- Implied R per inch = label R ÷ label thickness30 ÷ 9.5 in = 3.158
- Thickness = R to add ÷ R per inch49 ÷ 3.158 = 15.52 in
How it works
Enter the R-value and thickness printed on the product’s package or fact sheet. The tool works out the product’s R-value per inch and the thickness needed to add the difference between your target and any existing insulation:
- R to add = target − existing
- Thickness = R to add ÷ (label R ÷ label thickness)
It also shows how many full layers of the product that takes.
Use the label, not a generic table
The Federal Trade Commission’s R-value rule requires insulation packages to show the R-value and thickness (for batts) or the settled thickness and coverage at R-13 to R-49 (for loose fill), and limits per-inch claims because some products lose R-value per inch as they get thicker. That is why no generic R-per-inch table is built in. For loose fill, read the thickness straight from the bag’s chart at your target.
Compression and gaps
Squeezing a batt into a shallower cavity lowers its R-value: an R-19 batt in a 3½ inch stud cavity is rated about R-13. Gaps, voids and settling also reduce the installed R-value.
Worked example
These are the example values the calculator opens with, and the result the engine calculates for them.
Inputs
- Product label R-value
- 30 h·ft²·°F/BTU
- Thickness for that label R-value
- 9.5 in
- Existing R-value to keep
- 0 h·ft²·°F/BTU
- Target total R-value
- 49 h·ft²·°F/BTU
Result
- Thickness to add
- 15.5 in
- R-value to add
- 49 h·ft²·°F/BTU
- Full layers of this product
- 2
- Implied R-value per inch of this product
- 3.16 per in
About 15.5 in of this product adds R-49 (2 layers of the R-30 product).
Assumptions
- Thickness scales in proportion to R-value for the product you choose, at the R-value per inch implied by its label.
Limitations
- No material R-per-inch table is built in; FTC rules restrict per-inch claims, so use the product’s own label or fact sheet.
- Settling, compression, gaps and framing reduce installed R-value.
Frequently asked questions
How thick is R-49 fibreglass?
Using an R-30 batt labelled 9.5 inches, R-49 works out to about 15.5 inches, which matches the standard thickness listed for R-49 batts in the Seattle Energy Code tables.
Can I just add the R-values of two layers?
Yes. R-values in series add, so new insulation laid over existing insulation adds its R-value to the existing one.
Why does the tool round layers up?
Batts come in fixed thicknesses, so reaching the target with one product usually means a whole number of layers.
Sources
- 16 CFR Part 460 — Labeling and Advertising of Home Insulation (§ 460.12 labels, § 460.20 R-value per inch) — U.S. Federal Trade Commission, via eCFR. Batt and blanket labels must show R-value, length, width, thickness and coverage; loose-fill labels show minimum settled thickness and coverage at R-13 to R-49; R-value-per-inch claims are not allowed unless tests show the per-inch value does not drop with thickness.
- 2021 Seattle Energy Code, Appendix A (A101.3 air films; Table A101.4 compressed batts) — City of Seattle, Department of Construction and Inspections. Default air-film R-values: 0.17 all exterior surfaces, 0.61 interior horizontal heat flow up, 0.92 interior horizontal heat flow down, 0.68 interior vertical; fibreglass batts R-30 at 9.5 in and R-49 at 15.5 in standard thickness; an R-19 batt in a 3.5 in cavity is rated R-13.
Spotted an error? Report a problem with this calculator — see our corrections policy.