Air Purifier CADR Calculator

Find the clean air delivery rate (CADR) a portable air cleaner needs for your room, or how many clean-air changes per hour a unit you are considering gives.

Method reviewed October 26, 2026. Version 1.0.0. How it works

Your inputs

Unit system

EPA’s sizing chart is based on CADR equal to two-thirds of the floor area with an 8 ft ceiling, which is 5 air changes per hour.

Use the smoke CADR for smoke; 0 to skip.

Result

Minimum CADR
200CFM

A 300 ft² room with 8 ft ceilings needs about 200 CFM CADR for 5 clean-air changes per hour.

  • Higher ceilings need a higher CADR, as EPA notes. Run the unit on the speed whose CADR you used, and close the room if you can.
Show the working
  1. Room volume = area × ceiling height
    2,400 ft³
  2. CADR = volume × air changes per hour ÷ 60
    2,400 × 5 ÷ 60 = 200 CFM

Sizing by CADR

CADR is the rate at which an air cleaner delivers filtered air, in cubic feet per minute. EPA’s guide to air cleaners recommends a CADR large enough for the room, and its sizing chart works out to a CADR of two-thirds of the floor area with an 8 ft ceiling — about 5 clean-air changes per hour.

This calculator uses the room volume, so it adjusts for ceilings higher or lower than 8 ft: CADR = area × ceiling height × air changes per hour ÷ 60.

Getting the rated performance

CADR is measured in a test chamber. In a real room, open doors, air leaks and running the unit on a lower speed reduce its effect. For smoke, use the smoke CADR; for pollen or dust, the corresponding rating.

Worked example

These are the example values the calculator opens with, and the result the engine calculates for them.

Inputs

Room floor area
300 ft²
Ceiling height
8 ft
Target clean-air changes per hour
5
CADR of a unit you are considering (optional)
0 CFM

Result

Minimum CADR
200 CFM

A 300 ft² room with 8 ft ceilings needs about 200 CFM CADR for 5 clean-air changes per hour.

Assumptions

  • Clean-air changes per hour = CADR × 60 ÷ room volume. EPA’s chart assumes an 8 ft ceiling.

Limitations

  • CADR ratings are measured in a test chamber; real rooms with doors open or air leaks get less benefit.

Frequently asked questions

What CADR do I need for a 300 sq ft room?

About 200 CFM with an 8 ft ceiling — two-thirds of the floor area. With higher ceilings you need proportionally more.

Is a higher CADR always better?

A higher CADR cleans the air faster. The trade-offs are noise and energy; many people run a larger unit on a quieter setting.

Can my HVAC filter do the same job?

A good filter in a forced-air system helps whenever the fan runs. EPA’s guide covers both portable cleaners and HVAC filters.

Sources

  1. Guide to Air Cleaners in the Home — U.S. EPA. Choose a portable air cleaner with a CADR large enough for the room; EPA’s sizing chart assumes an 8 ft ceiling, and higher ceilings need a higher CADR.
  2. Choosing a Portable Air Cleaner — Washington State Department of Health. A smoke CADR of at least two-thirds of the room area cleans the air about 5 times per hour with an 8 ft ceiling.

Spotted an error? Report a problem with this calculator — see our corrections policy.